Skip to content

Lecture notes. Written from the material of StatOmics Sga21, licensed CC BY-NC-SA 4.0. These are notes, not a transcript: the material has been reorganised and rewritten. This adaptation carries the same licence, and the original is linked above.

9. Illumina Next-Generation Sequencing Overview

What this covers

Before any statistical method for read counts, base calls, or variant calls makes sense, a more basic question has to be settled: what actually happens between a tube of DNA or RNA and the data a downstream analysis works with? This chapter walks through Illumina's sequencing-by-synthesis chemistry, the four-step workflow that turns a sample into reads, the main families of experiments the technology supports — genomics, transcriptomics, epigenomics — and the vocabulary needed to read a methods section (coverage, insert, cluster, index, and so on). It assumes only familiarity with DNA/RNA structure, PCR, and the idea of aligning a sequence read to a reference genome; it assumes nothing about sequencing instruments themselves.

From capillary electrophoresis to massively parallel sequencing

DNA sequencing before the 2000s was a "first-generation" technology. Sanger's chain-termination method (1977) made sequencing reliable and reproducible, and a decade later Applied Biosystems built automated, capillary-electrophoresis (CE) instruments around it — the AB370 (1987) and the AB3730xl (1998) — which became the workhorses of the NIH-led and Celera-led Human Genome Project. Those instruments were high throughput for their time, but they still sequenced one fragment at a time.

The break came in 2005, with the Genome Analyzer: instead of sequencing a single fragment, it sequenced millions of fragments in parallel, and a single run went from roughly 84 kilobases of output to about 1 gigabase. That short-read, massively parallel approach is what "next-generation sequencing" (NGS) refers to, and from that point the data output of NGS more than doubled every year — outpacing Moore's law. By 2014, a single run produced 1.8 terabases, a roughly \(1000\times\) increase over 2005.

The same period tells the story in cost. The first human genome, published in 2001, took fifteen years and cost nearly three billion dollars. By 2014, the HiSeq X Ten system could sequence over 45 human genomes in a single day for approximately $1000 each. That drop is what people mean by "the $1000 genome": it is not just cheaper sequencing, it is what makes population-scale sequencing and routine clinical genomics possible, because a lab can now run thousands to tens of thousands of samples in a year rather than one genome over a decade and a half. As Eric Lander (Broad Institute, and a leader of the Human Genome Project) put it:

"The rate of progress is stunning. As costs continue to come down, we are entering a period where we are going to be able to get the complete catalog of disease genes. This will allow us to look at thousands of people and see the differences among them, to discover critical genes that cause cancer, autism, heart disease, or schizophrenia."

The core chemistry: sequencing by synthesis

The chemical idea behind NGS is the same one CE sequencing already used: a DNA polymerase incorporates fluorescently labelled nucleotides (dNTPs) into a growing strand, and at each incorporation the identity of the base is read off from the fluorophore. The difference is scale — NGS runs this cycle across millions of DNA fragments simultaneously rather than one at a time. Over 90% of the world's sequencing data comes from Illumina's sequencing-by-synthesis (SBS) chemistry, which uses a reversible-terminator nucleotide: all four labelled, terminator-bound bases are present at once during a cycle, so they compete for incorporation, which is what keeps incorporation bias and raw error rates low even in repetitive sequence and homopolymer runs. After each base is incorporated and imaged, the terminator and dye are cleaved so the next cycle can proceed.

That single-base chemistry sits inside a four-stage workflow that is the skeleton of every Illumina NGS method, whatever the downstream question:

  1. Library preparation — the sample (DNA or cDNA) is randomly fragmented, and adapters are ligated to the \(5'\) and \(3'\) ends of each fragment. "Tagmentation" is a faster variant that fragments and ligates in a single step. Adapter-ligated fragments are then PCR-amplified and purified.
  2. Cluster generation — the library is loaded onto a flow cell, a glass slide whose surface is coated with oligos complementary to the adapters. Each library molecule binds the surface, and its free end bends over and "bridges" to a neighbouring complementary oligo. Repeated cycles of denaturation and extension — bridge amplification — turn each single template molecule into a clonal cluster of about a thousand copies, so that its signal is strong enough to detect. A cluster is what a single template becomes; it is also what will produce a single sequencing read.
  3. Sequencing — the reversible-terminator SBS chemistry described above is run simultaneously across every cluster on the flow cell.
  4. Data analysis — reads are aligned to a reference genome, and everything downstream — variant calling, read counting, phylogenetic or metagenomic analysis — starts from that alignment.
Library preparation Cluster generation Sequencing (SBS) Data analysis fragment + adapter bridge amplification read-out per cycle align to reference
The workflow shared by every Illumina NGS method: only the library preparation step changes between whole-genome sequencing, RNA-seq, methylation sequencing, and the rest.

What changed on top of that core chemistry

Several advances sit on top of the basic SBS cycle and explain why NGS displaced CE sequencing rather than merely competing with it.

Paired-end sequencing reads both ends of each library fragment and aligns them as a pair. This doubles the number of reads for the same library preparation effort, but the more important gain is information: because the distance between the two ends is roughly known, paired reads align more accurately across repetitive regions, make indel detection possible (which single-end reads cannot do), let PCR duplicates be identified from anomalous pair spacing, and increase the number of usable SNV calls. Some methods, such as small RNA sequencing, are still better served by single-end reads, but paired-end is now the default for most applications.

Tunable, digital coverage. A microarray reports a continuous intensity, bounded below by noise and above by saturation. NGS instead counts discrete reads, so its dynamic range is set only by how many reads are collected — and that can be dialled up or down to match the question. Detecting a somatic mutation present in only a small fraction of cells in a tumour–normal mixture needs very deep coverage of the region in question, often upwards of \(1000\times\); discovering variants across a population needs the opposite trade-off, spreading reads thinly (lower depth per sample) but across many samples to gain statistical power. The same chemistry supports both, just by changing how sequencing effort is allocated.

Faster, cleaner library preparation. Early NGS libraries took one to two days to prepare, an improvement on cloning-based approaches but still a bottleneck; kits such as Nextera XT brought this under 90 minutes, and PCR-free protocols avoid the amplification bias that otherwise degrades coverage of GC/AT-rich regions, promoters, and homopolymers.

Multiplexing. Because each library fragment can carry a short (8–12 bp) index sequence added during library preparation, many libraries can be pooled and run in a single flow cell lane, then computationally sorted ("demultiplexed") afterwards. This is what makes running hundreds of samples in one instrument run practical. It also introduces a specific failure mode, index misassignment ("index hopping"): a read's index sequence gets attached to the wrong library during pooling or sequencing, so it is assigned to the wrong sample downstream.

Scalable instrumentation. The chemistry is the same across a benchtop instrument producing a few gigabases for a targeted panel and a production-scale instrument producing terabases across population-scale studies; what differs is flow cell design and run configuration, so the same methodology development carries across the range of scale a lab might need.

Applications I: genomics

Whole-genome sequencing (WGS) reads the full genome rather than a fixed panel of markers, which is what a genotyping microarray does. Its cost has fallen enough that it is now practical not just for human genomes but for any organism — including, for example, the rapid strain-level sequencing used to trace the source and virulence of the 2011 European E. coli outbreak.

Exome sequencing (WES) sequences only the protein-coding exome, under 2% of the genome by size but the location of most known disease-causing variants, making it a cheaper alternative to WGS for many disease and population-genetics questions.

De novo sequencing applies when there is no reference genome to align to, so reads must instead be assembled into overlapping contigs from scratch. Assembly quality depends on the diversity of insert sizes in the library: short-insert paired-end reads, sequenced at high depth, resolve fine detail, while long-insert mate-pair libraries (2–5 kb gaps between the paired reads), sequenced at lower depth, span the repetitive regions that short inserts cannot bridge and let structural variants be detected. Combining both is the standard route to a good assembly.

Targeted sequencing captures and sequences only a chosen subset of the genome, which lets the same sequencing budget buy much higher depth: a typical WGS study covers each base \(30\)–\(50\times\), while a targeted panel can reach \(500\)–\(1000\times\) or more, which is what makes detecting rare variants affordable. There are two ways to do this: target enrichment (hybridisation capture of a region anywhere from 10 kb to 62 Mb) and amplicon sequencing (highly multiplexed PCR of 16 up to 1536 specific targets). Amplicon panels are the standard approach both for finding rare somatic mutations in a tumour sample diluted by normal DNA, and for surveying the bacterial 16S rRNA gene across many species at once in metagenomic samples.

Applications II: transcriptomics

RNA-seq library preparation typically starts from total RNA, removes ribosomal RNA, and converts the remainder to cDNA before standard NGS library prep; which additional enrichment step is added before that conversion determines which slice of the transcriptome is captured.

Total RNA and mRNA sequencing give a snapshot of the whole transcriptional state of a sample rather than a fixed, pre-chosen set of genes — the same digital-counting advantage described above lets rare and common transcripts both be quantified in the same run, and reads spanning splice junctions support detection of isoforms, novel transcripts, and gene fusions.

Targeted RNA sequencing restricts this to a chosen panel of transcripts — useful for measuring differential expression, allele-specific expression, fusions, or splice junctions within a pathway of interest, and for validating results from an array or whole-transcriptome experiment more cheaply.

Small RNA and noncoding RNA sequencing targets the 18–22 bp microRNAs, which act largely as gene repressors and silencers; their role in transcriptional and translational regulation is the reason this has become its own sequencing category rather than a byproduct of total RNA-seq.

Applications III: epigenomics

Epigenomics studies heritable changes in gene activity that are not changes in the DNA sequence itself — methylation, small-RNA regulation, DNA–protein binding, histone modification.

Methylation sequencing reads cytosine methylation (5mC) at single-base resolution, genome-wide. Two protocols dominate: whole-genome bisulfite sequencing (WGBS) treats DNA with sodium bisulfite, which converts unmethylated cytosines to uracil (read out as thymine after sequencing) while leaving methylated cytosines unchanged, so methylation status is read directly from the sequence; reduced representation bisulfite sequencing (RRBS) first digests DNA with the enzyme MspI — which is insensitive to methylation status — and keeps only the 100–150 bp fragments enriched for CpG-rich, promoter-proximal DNA, then applies the same bisulfite step to a much smaller, cheaper library.

ChIP sequencing combines chromatin immunoprecipitation with sequencing to map where a protein of interest binds DNA (or RNA) genome-wide; the immunoprecipitation step is specific to the protein, species, and tissue, and only the resulting fragments enter a standard NGS library prep.

Ribosome profiling sequences the mRNA fragments physically protected by a bound ribosome, giving a genome-wide snapshot of which transcripts are being actively translated at a given moment — useful for studying translational control, estimating protein synthesis rates, and predicting protein abundance directly, rather than inferring it from mRNA levels alone.

From reads to data: the workflow around the chemistry

The four-step chemistry above sits inside a larger pipeline built to move data off the instrument and into analysis with as little manual handling as possible. Library preparation kits exist for every method above, scaled from manual protocols for small labs to automated workstations for large sequencing centres; sequencing platforms range correspondingly from benchtop instruments to production-scale systems. Illumina's cloud platform (BaseSpace Sequence Hub, with an on-site variant for labs that need to keep data local) streams data straight off the instrument and offers a standard set of downstream applications — alignment and variant calling, RNA expression profiling, 16S metagenomics, tumour–normal comparison, epigenetic analysis — built by Illumina and third-party developers on a common infrastructure, so that the specific method chosen at the library-preparation step is what determines the downstream analysis, not a change in instrument or chemistry.

Glossary

A short reference for terms that recur across methods sections without necessarily being defined each time:

  • Adapter — the oligo ligated to each end of a library fragment, complementary to the lawn of oligos on the flow cell surface.
  • Insert — the original sample fragment sitting between the two adapters (typically 200–500 bp, or 2–5 kb for a mate-pair library).
  • Cluster — the clonal group of roughly a thousand copies of one template molecule, produced by bridge amplification on the flow cell; one cluster produces one read (two, if paired-end). 10,000 clusters therefore give 10,000 single reads or 20,000 paired-end reads.
  • Flow cell — the glass slide, divided into one to eight lanes, whose surface carries the adapter-complementary oligo lawn that clusters form on.
  • Coverage (depth) — the average number of sequenced bases aligning to each reference base; "\(30\times\) coverage" means each base was sequenced 30 times on average.
  • Index / barcode / tag — a short (8–12 bp) sequence added to a library during preparation so that pooled ("multiplexed") libraries can be sorted computationally after sequencing.
  • Contig — a stretch of continuous sequence assembled in silico from overlapping reads, used when there is no reference to align to.
  • Reference genome — the assembled genome that new reads are aligned against as the first step of most downstream analyses.
  • Mate-pair library — a paired-end library with a long (2–5 kb) gap between the two ends, useful for spanning repeats during de novo assembly and for detecting larger structural variants.

Sources

All material in this chapter comes from a single document supplied as course reading, split by the converter into five files, all part of omics-statistics/statomics/sga21:

  • Section I (evolution of genomic science, SBS chemistry basics, paired-end sequencing, dynamic range, library-prep advances, multiplexing, instrumentation) — illumina_sequencing_introduction/01-i-welcome-to-next-generation-sequencing.md.
  • Section II (genomics, transcriptomics, epigenomics methods) — illumina_sequencing_introduction/02-ii-ngs-methods.md.
  • Section III (the Illumina DNA-to-data workflow and BaseSpace) — illumina_sequencing_introduction/03-iii-illumina-dna-to-data-ngs-solutions.md.
  • Section IV (glossary) — illumina_sequencing_introduction/04-iv-glossary.md.
  • Section V (numbered references, e.g. Sanger et al. 1977 on chain-termination sequencing, Bentley et al. 2008 on reversible-terminator chemistry, Grad et al. 2012 on the 2011 E. coli outbreak) — illumina_sequencing_introduction/05-v-references.md.

The source is an Illumina white paper ("Welcome to Next-Generation Sequencing"), converted from a PDF with no extractable text layer; the conversion note on each file flags the prose as a paraphrase in places and every equation as unverified, so numeric claims here should be checked against the original PDF (linked from each file's front matter) before being cited further. No slide deck, transcript, or exercise set was supplied alongside this reading.


← 8. Interaction Effects and Stage-wise Testing · Contents · 10. Course Description and Program →